C Module

Measurement Module

The C Module launched by VCARSYSTEM, which can collect temperature, analog voltage/current signal, air-fuel ratio, frequency, turbine speed and other physical quantity signals, and output them in real time through CAN bus signal.

C Module Types

  • C-AD4 /8

    AD Module

    A data signal acquisition device with 4 /8 voltage input channels, and a highly compact module supporting CAN protocol communication.

    Features

    4 /8-Channel voltage input
    Voltage measurement
    Analog voltage input
    Measurement range: ±60V, ±10V adjustable
    Measurement accuracy: ±10mv, 5mv (-40 ℃ ~ + 85 ℃ )
    Sampling rate: configurable from 1Hz to 1kHz
    Data transmission cycle: 1ms~ 1s
    Adjustable sampling resolution: 24 bit
    Sensor supply voltage: adjustable from 5V to 24V
    Supports multiple modules in series to collect more signals
    Electrical isolation (input, CAN , power supply, enclosure)
    Environmentally friendly designed for harsh conditions with a high waterproof and dustproof rating

    Application scenarios

    Vehicle Data Acquisition
    Vehicle Energy Flow Management
  • C-Thermo-K10 /20

    Temperature Module

    A data signal acquisition device with 10 /20-channel temperature measurement and a highly compact module supporting CAN protocol communication.

    Features

    10 /20-Channel temperature input
    Temperature measurement
    K-type thermocouple differential input (NiCr-Ni)
    Measurement range: -100 ℃ ~ + 1250 ℃
    Measurement accuracy: 1 ℃ (ambient temperature:-40℃ ~ + 85℃ )
    Data transmission cycle: 100ms -5000ms
    Sampling rate: configurable from 0.2Hz to 10Hz
    Sampling resolution: 16bit
    Display resolution: 0.1 ℃
    Supports multiple modules in series to collect more signals
    Electrical isolation (input, CAN , power supply, enclosure)
    Environmentally friendly design for harsh conditions with a high waterproof and dustproof rating

    Application scenarios

    Vehicle Data Acquisition
    Vehicle Energy Flow Management
  • C-lambda

    Lambda Module

    A data signal acquisition device for monitoring air-fuel ratio, a highly compact module that supports CAN protocol communication.

    Features

    1-Channel linear oxygen sensor interface
    Air-fuel ratio measurement
    Input: continuous Oxygen Sensor LSU4.2 or LSU4.9
    For LSU4.9, λ measurement range 0.55 -32.767
    Measurement accuracy: IP accuracy 0.1% 0.007mA, (When λ Approximately equal to 1, the λ accuracy is 0.005)
    Sampling frequency: 100Hz
    Sampling resolution: 16bit
    Data transmission cycle: 10ms
    Supports multiple modules in series for collecting more signals
    Electrical isolation (input, CAN , power supply, enclosure)
    Features a high waterproof and dustproof rating, suitable for harsh environments

    Application scenarios

    Vehicle Exhaust Measurement
    Vehicle Data Acquisition
  • C-FREQ

    Frequency Module

    A data signal acquisition device for monitoring frequency, a highly compact module that supports CAN protocol communication.

    Features

    4-Channel FREQ input
    Frequency measurement
    Input: 4-channel FREQ input
    Measurement range: 0.1~ 300KHz
    Input signal voltage range: ±60V,adjustable for high and low level thresholds
    Sampling rate: adjustable from 1ms to 1s
    Sampling resolution: 16 bit
    Sensor supply voltage: adjustable from 5V to 24V
    Supports serial connection of multiple modules for collecting more signals
    Electrical isolation (input, CAN , power supply, enclosure)
    Possesses a high waterproof and dustproof rating, suitable for use in harsh environments

    Application scenarios

    Vehicle Data Acquisition
    Vehicle Energy Flow Management
  • C-PT100

    PT Module

    A data signal acquisition device with a temperature input channel and a highly compact module that supports CAN protocol communication.

    Features

    4-channel PT sensor interface
    Temperature measurement
    Input: 4-channel PT100 input,compatible with 2, 3, and 4-wire systems
    Measurement range: -200 ℃ ~ + 850 ℃
    Measurement accuracy:+0.2℃ (ambient temperature: -40 ℃ ~ 85 ℃ )
    Data transmission cycle: configurable from 70ms to 10s
    Sampling rate: configurable from 0.1Hz to 10Hz
    Hardware sampling resolution : 24 bit
    Display resolution : 0.1°C
    Sensor power supply voltage : adjustable from 5V to 24V
    Supports serial connection of multiple modules for collecting more signals
    Electrical isolation (input, CAN , power supply, enclosure)
    Features a high waterproof and dustproof rating, suitable for use in harsh environments

    Application scenarios

    Vehicle Data Acquisition
    Vehicle Energy Flow Management
  • C-Multi LTK10

    Aggregate Module

    A data signal acquisition device with temperature, air-fuel ratio and turbine speed input channels, and a highly compact module supporting CAN protocol communication.

    Features

    10-Channel temperature input , 1 linear oxygen sensor interface, 1 speed sensor interface
    Temperature measurement
    Input: K-type thermocouple differential input (NiCr-Ni)
    Measurement range: -100 ℃ ~ + 1250 ℃
    Measurement accuracy: 1℃ (ambient temperature: -40 ℃ ~ + 105 ℃ )
    Data transmission period: adjustable from 100ms to 5000ms
    Sampling frequency: adjustable from 0.2Hz to 10Hz
    Turbocharger speed measurement
    Input: turbocharger speed signal
    Speed measurement range (under conditions of 10 blades) : 0 RPM to 320,000 RPM; resolution: 12 RPM
    Speed measurement range (under the condition of 30 blades): 0 RPM~ 100000 RPM: resolution: 4RPM; accuracy: 0.25%
    Air-fuel ratio measurement
    Input: continuous Oxygen Sensor LSU4.2, LSU4.9
    Sampling frequency: 100Hz
    The measurement range is 0.55—32.767
    Measurement accuracy: IP accuracy 0.1% + 0.007mA, (When λ Approximately equal to 1, the λ accuracy is 0.005).
    Supports serial connection of multiple modules for collecting more signals
    Electrical isolation (input, CAN , power supply, enclosure)
    Features a high waterproof and dustproof rating, suitable for use in harsh environments

    Application scenarios

    Vehicle Data Acquisition
    Vehicle Energy Flow Management
    High Voltage Scenarios
  • HV-MODULE

    High Voltage Module

    A data signal acquisition device with a high voltage input channel, and a highly compact module supporting CAN protocol communication.

    Features

    1-channel high voltage circuit interface
    Voltage measurement
    Input: analog voltage input
    Measurement range: ± 1100V
    Measurement accuracy: ± 2V (-40 ℃~ 85 ℃ )
    Sampling rate: 1Hz~ 1kHz
    Sampling resolution: 24bit
    Input cutoff frequency: 2KHz
    Input Impedance: 21MΩ
    Supports serial connection of multiple modules for collecting more signals
    Electrical isolation (input, CAN , power supply, enclosure)
    Features a high waterproof and dustproof rating, suitable for use in harsh environments

    Application scenarios

    Vehicle Data Acquisition
    Vehicle Energy Flow Management

SUPPORT

Copyright © 2024 VCARSYSTEM All rights reserved.